The AMBU Cadmium Voltmeter
Fig. 121 is a view of the special AMBU Voltmeter, which is designed to be used specially in making Cadmium tests. Fig. 122 shows the Cadmium leads. The four red lines marked “Neg. Charged,” “Neg. Discharged,” “Pos. Charged,” and “Pos. Discharged,” indicate the readings that should be obtained. Thus, in testing the positives of a battery on charge, the pointer will move to the line which is marked “Pos. Charged,” if the positive plates are fully charged. In testing the negatives, the pointer will move to the line marked “Neg. Charged,” which is to the left of the “0” line, if the negatives are fully charged, and so on. Figs. 123, 124, 125 and 126 show the pointer in the four positions on the scale which it takes when testing fully charged or discharged plates. In each figure the pointer is over one of the red lines on the scale. These figures also show the readings, in volts, obtained in making the cadmium tests on fully charged or completely discharged plates.
If Pointer Is Not Over the “0” Line: It sometimes happens, in shipping the instrument, and also in the use of it, that the pointer does not stand over the “0” line, but is a short distance away. Should you find this to be the case, take a small screwdriver and turn the screw which projects through the case, and which is marked “Correct Zero,” so as to bring the pointer exactly over the “0” line on the scale while the meter has no wires connected to its binding posts.
Connections of Cadmium Leads: In making Cadmium Tests, connect the prod which has the cadmium fastened to it to the negative voltmeter binding post. Connect the plain brass prod to the positive voltmeter binding post. The connections to the AMBU Cadmium Voltmeter are shown in Fig. 127.