Series on 115 Volt Line
| Amp. Hours Capacity 5 Amp. Rate | Amperes Approximate | No. of Cells in Series on Line 115-Volt | No. 115 Volt Lamps Required 115-Volt |
|---|---|---|---|
| 50 or less | 0.05 | 3 | 5-15 watt, in series |
| 50 or less | 0.05 | 30 | 2-15 watt, in series |
| 50 or less | 0.05 | 45 | 1-15 watt, in series |
| 50-100 | 0.10 | 3 | 3-25 watt, in series |
| 50-100 | 0.10 | 3 | 1-25 watt, in series |
| 50-100 | 0.10 | 45 | 2-25 watt, in parallel |
| 100 or over | 0.15 | 3 | 2-25 watt, in series |
| 100 or over | 0.15 | 30 | 1-25 watt, in series |
| 100 or over | 0.15 | 45 | 3-25 watt, in parallel |
Every two months interrupt the trickle charge long enough to add water to bring the electrolyte up to the proper level. When this has been done, continue the trickle charge.
Before putting the batteries into service, see that the electrolyte is up to the correct level, and that the specific gravity of the electrolyte is 1.280-1.300. If necessary, give a short charge on the charging bench to bring the specific gravity up to the correct value.